European Journal of Vascular & Endovascular Surgery
Volume 17, Issue 1 , Pages 5-8, January 1999

Disruption of Skin Perfusion Following Longitudinal Groin Incision for Infrainguinal Bypass Surgery

  • Z Raza

      Affiliations

    • Vascular Laboratory, Directorate of General Surgery, Dundee Teaching Hospitals NHS Trust, Ninewells Hospital and Medical School, Dundee, U.K.
  • ,
  • D.J Newton

      Affiliations

    • Vascular Laboratory, Directorate of Medical Physics, Dundee Teaching Hospitals NHS Trust, Ninewells Hospital and Medical School, Dundee, U.K.
  • ,
  • D.K Harrison

      Affiliations

    • Vascular Laboratory, Directorate of Medical Physics, Dundee Teaching Hospitals NHS Trust, Ninewells Hospital and Medical School, Dundee, U.K.
  • ,
  • P.T McCollum

      Affiliations

    • Vascular Laboratory, Directorate of General Surgery, Dundee Teaching Hospitals NHS Trust, Ninewells Hospital and Medical School, Dundee, U.K.
  • ,
  • P.A Stonebridge

      Affiliations

    • Vascular Laboratory, Directorate of General Surgery, Dundee Teaching Hospitals NHS Trust, Ninewells Hospital and Medical School, Dundee, U.K.

Accepted 25 May 1998.

Article Outline

Abstract 

Objectivethe objective of our study was to investigate whether such an incision results in a reduction in blood flow, and therefore haemoglobin oxygen saturation, across the wound.Designmicrovascular oxygenation was measured with lightguide spectrophotometry in 21 patients undergoing femoropopliteal or femorodistal bypass procedures. A series of measurements were made in the groin, medial and lateral to the surface marking of the femoral artery. The mean oxygen saturation on each side was calculated, and the contra-lateral groin was used as a control. The measurements were repeated at 2 and 7 days postop.Resultsoxygen saturation in the skin of the operated groins was increased significantly from baseline at 2 days postop (f=25.80, p<0.001) and had begun to return to normal by day 7. The rise was more marked on the lateral side of the wound than on the medial (f=12.32, p<0.001). There was no such difference in the control groins. All wounds healed at 10 days.Conclusionsthese results show a significant difference in skin oxygenation between the lateral and medial sides of the groin following longitudinal incision. This may contribute to the relatively high incidence of postoperative infection in these wounds.

Keywords: Groin, Infrainguinal, Wound infection, Oxygenation, Spectrophotometry.

No full text is available. To read the body of this article, please view the PDF online.

 

Back to Article Outline

References 

  1. Newington DP, Houghton PWJ, Baird RN, Horrocks M. Groin wound infection after arterial surgery. Br J Surg. 1991;78:617–619
  2. Chamberlain, J. Sepsis. In: Galland RB, Clyne CAC eds.Clinical Problems in Vascular Surgery, 1994, 71, 78
  3. Jamieson GG, De Weese JA, Rob CG. Infected arterial grafts. Ann Surg. 1975;181:850–852
  4. Bennion RS, Hiatt JR, Williams RA, Wilson SE. Surgical management of ulilateral groin infection after aortofemoral bypass. Surg Gyn Obs. 1983;156:724–728
  5. McGregor IA, Jackson IT. The groin flap. Br J Plas Surg. 1972;25:3–16
  6. Harrison DK, McCollum PT, Newton DJ, Hickman P, Jain AS. Amputation level assessment using lightguide spectrophotometry. Prosthet Orthot Int. 1994;19:139–147
  7. Newton DJ, Harrison DK, Hanna GB, Thompson CJA, Belch JJF, McCollum PT. Microvascular blood flow and oxygen supply in ulcerated skin of the lower limb. Adv Exp Med Biol. 1997;428:21–26
  8. Hanna GB, Newton DJ, Harrison DK, Belch JJF, McCollum PT. Use of lightguide spectrophotometry to quantify skin oxygenation in a variable model of venous hypertension. Br J Surg. 1995;82:1352–1356
  9. Forrester, JC. Wounds and their management.In: Cuschieri A, Giles GR, Moussa AR eds.Essential Surgical Practice (2nd edition), 1988, 3, 15
  10. Merschbrock U, Hoffmann J, Caspary L, Huber J, Schmickaly U, Lübbers DW. Fast wavelength scanning reflectance spectrophotometer for non-invasive determination of hemoglobin oxygenation in human skin. Int J Microcirc. 1994;14:274–281
  • f1 Please address all correspondence to: D. J. Newton, Vascular Laboratory, Ninewells Hospital and Medical School, Dundee DD1 9SY, U.K.

PII: S1078-5884(98)90651-7

doi:10.1053/ejvs.1998.0651

European Journal of Vascular & Endovascular Surgery
Volume 17, Issue 1 , Pages 5-8, January 1999