Advertisement
Research Article| Volume 44, ISSUE 1, P77-81, July 2012

Endovenous Simulated Laser Experiments at 940 nm and 1470 nm Suggest Wavelength-Independent Temperature Profiles

Open ArchivePublished:May 23, 2012DOI:https://doi.org/10.1016/j.ejvs.2012.04.017

      Abstract

      Background

      EVLA has proven to be very successful, but the optimum methods for energy delivery have still not been clarified. A better understanding of the mechanism of action may contribute to achieving a consensus on the best laser method and the most effective use of laser parameters, resulting in optimal clinical outcomes, maintaining high success rates with minimal adverse events. The aim of this study is to assess the impact of wavelength, pullback speed and power level on the endovenous temperature profile in an experimental setting.

      Methods

      In an experimental setting, temperature measurements were performed using thermocouples. The experimental set-up consisted of a transparent box in which a glass tube was fixed. Different laser parameters (wavelength and power) and 2 different pullback speeds (2 and 5 mm/s) were used. Thermocouples were placed at different distances from the fiber tip. Validity of the experimental setting was assessed by performing the same temperature measurements using a stripped varicose vein. The maximal temperature rise and the time span that the temperature was above collagen denaturation temperature were measured.

      Results

      The experiments showed that decreasing the pullback speed (2 mm/s) and increasing the power (up to 14 W) both cause higher maximal temperature and a longer time above the temperature for collagen denaturation. The use of different laser wavelengths (940 or 1470 nm) did not influence the temperature profile.

      Conclusion

      The results of our experiments show that wavelength on its own has not been demonstrated to be an important parameter to influence the temperature profile.

      Keywords

      Endovenous laser ablation (EVLA) is most frequently used as thermal therapy for saphenous varicose veins. EVLA is a challenging traditional surgery as the gold standard for varicose vein treatment because of its very high success rate (>90%),
      • van den Bos R.
      • Arends L.
      • Kockaert M.
      • Neumann M.
      • Nijsten T.
      Endovenous therapies of lower extremity varicosities: a meta-analysis.
      low rates of complications
      • Van Den Bos R.R.
      • Neumann M.
      • De Roos K.P.
      • Nijsten T.
      Endovenous laser ablation-induced complications: review of the literature and new cases.
      and recurrences. Although EVLA has proven to be very successful, the exact working mechanism is still not fully identified, and the procedure is, therefore, not yet standardised (i.e., wavelength, pullback speed and power). Several studies, some of them retrospective cohort analyses, suggest that a minimal energy delivery of 60 J cm−1 should be administered to achieve occlusion of a vein.
      • Proebstle T.M.
      • Moehler T.
      • Herdemann S.
      Reduced recanalization rates of the great saphenous vein after endovenous laser treatment with increased energy dosing: definition of a threshold for the endovenous fluence equivalent.
      • Timperman P.E.
      • Sichlau M.
      • Ryu R.K.
      Greater energy delivery improves treatment success of endovenous laser treatment of incompetent saphenous veins.
      • Theivacumar N.S.
      • Dellagrammaticas D.
      • Beale R.J.
      • Mavor A.I.
      • Gough M.J.
      Factors influencing the effectiveness of endovenous laser ablation (EVLA) in the treatment of great saphenous vein reflux.
      The lack of knowledge on working mechanism may have contributed to the commercially driven proliferation of different laser wavelengths and modifications such as fibre tips with radial emission of laser light.
      Thermal injury to the venous wall is generally accepted to be responsible for vein occlusion in endovenous thermal treatments. However, the exact mechanism of EVLA-induced temperature rise is not well documented. Four main theories on the heat induction of EVLA have been proposed: (1) direct absorption of the scattered laser light by the vein wall,
      • Mordon S.R.
      • Wassmer B.
      • Zemmouri J.
      Mathematical modeling of 980-nm and 1320-nm endovenous laser treatment.
      • Disselhoff B.C.
      • Rem A.I.
      • Verdaasdonk R.M.
      • Kinderen D.J.
      • Moll F.L.
      Endovenous laser ablation: an experimental study on the mechanism of action.
      (2) heat transport by steam bubbles emerging from the hot fibre tip and heat release associated with their condensation,
      • Proebstle T.M.
      • Lehr H.A.
      • Kargl A.
      • Espinola-Klein C.
      • Rother W.
      • Bethage S.
      • et al.
      Endovenous treatment of the greater saphenous vein with a 940-nm diode laser: thrombotic occlusion after endoluminal thermal damage by laser-generated steam bubbles.
      • van der Geld C.W.
      • van den Bos R.R.
      • van Ruijven P.W.
      • Nijsten T.
      • Neumann H.A.
      • van Gemert M.J.
      The heat-pipe resembling action of boiling bubbles in endovenous laser ablation.
      (3) direct contact of the laser fibre with the vein wall
      • Disselhoff B.C.
      • Rem A.I.
      • Verdaasdonk R.M.
      • Kinderen D.J.
      • Moll F.L.
      Endovenous laser ablation: an experimental study on the mechanism of action.
      • Fan C.M.
      • Rox-Anderson R.
      Endovenous laser ablation: mechanism of action.
      and (4) heat diffusion from the hot fibre tip.
      • van den Bos R.R.
      • Kockaert M.A.
      • Martino Neumann H.A.
      • Bremmer R.H.
      • Nijsten T.
      • van Gemert M.J.
      Heat conduction from the exceedingly hot fiber tip contributes to the endovenous laser ablation of varicose veins.
      Knowledge about heat generation and heat transport is important. Two studies measured intravenous temperatures during EVLA (810 and 980 nm) of 61–140 °C and perivenous temperatures of 35–48 °C.
      • Viarengo L.M.
      • Poterio-Filho J.
      • Poterio G.M.
      • Menezes F.H.
      • Meirelles G.V.
      Endovenous laser treatment for varicose veins in patients with active ulcers: measurement of intravenous and perivenous temperatures during the procedure.
      • Weiss R.A.
      Comparison of endovenous radiofrequency versus 810 nm diode laser occlusion of large veins in an animal model.
      • Zimmet S.E.
      • Min R.J.
      Temperature changes in perivenous tissue during endovenous laser treatment in a swine model.
      The effect of the various laser parameters that may affect the rise in temperature, such as wavelength, power level and pullback speed (which are not standardised in EVLA) is poorly documented. The aim of this study is to assess the impact of wavelength, pullback speed and power level on the endovenous temperature profile in an experimental setting.

      Methods

      The experimental set-up consisted of a transparent box in which a glass tube was fixed. The glass tube was open at both ends so that the laser fibre and some thermocouples were introduced from opposite ends. The box was filled with water (room temperature) and the tube was filled with heparinised pig blood. Three thermocouples were positioned within the tube (tc 1, 2, 3) and four thermocouples were positioned at the outside of the tube and at different distances from the tube wall (tc 4, 7: 0 mm, tc 5: 1 mm, tc 6: 2 mm) (Figs. 1 and 2). The internal thermocouples inside the tube were placed at three different positions because it was expected that the temperature profiles would differ for various axial positions due to development of the heat caused by the laser fibre moving from left to right. To assess the validity of the experimental setting, a stripped human great saphenous vein (GSV) was used for similar temperature measurements. In these experiments, thermocouples were placed inside the vein and at the outer surface of the vein. This was done since positioning thermocouples at a certain distance from the outer surface was not possible due to flexibility of the vein.
      Figure thumbnail gr1
      Figure 1Schematical representation of the experimental setup.
      Figure thumbnail gr2
      Figure 2Position of the thermocouples and fiber with definition of the radial distance, r.
      Two laser wavelengths were used: 940 nm (Diode, Dornier Diomed LTD) and 1470 nm (neodymium:yttrium–aluminium–garnet, ELVeS Biolitec AG, Germany). To assure a centred position of the laser fibres in the tube (i.e., fixed distance to the thermocouples), the end-emitting laser fibres (core diameter of 0.6 mm) were centred in the tube using a ‘tulip’ piece attached to the fibre tip.
      • Vuylsteke M.
      • Van Dorpe J.
      • Roelens J.
      • De Bo T.
      • Mordon S.
      • Fourneau I.
      Intraluminal fibre-tip centring can improve endovenous laser ablation: a histological study.
      We used a new fibre after two experiments, after one experiment the tip was cleft. The temperature experiments were repeated for two pullback speeds, v, (2 and 5 mm s−1), two laser wavelengths, λ, (940 and 1470 nm) and several values for laser power, P (continuous mode). The measured output was different from the power setting. At 940 nm the measured power was 4.58 W at a power setting of 5 W, 12.8 W (setting 14 W) and 18.3 W (setting 20 W). At 1470 nm, the measured output was 4.6 W (setting 5 W) and 12.7 W (setting 14 W). For each of the 10 possible combinations of parameters, temperature measurements were repeated 5 times. To assess the endovenous temperature profile, ΔTmax and Δtden were calculated from this graphical representation. ΔTmax was defined as the maximal temperature increase above the initial temperature (about 20 °C) measured by any of the thermocouples inside the tube and by the outer thermocouples, and Δtden was defined as the time span that the temperature was above 50 °C (i.e., temperature at which collagen denatures). This time span reflects the damage to the collagen of the vein wall, which is assumed to be required for successful thermal ablation.
      • Biesman B.S.
      • Khan J.
      Laser incisional surgery.
      • Moritz A.R.
      • Henriques F.C.
      Studies of thermal injury: II. The relative importance of time and surface temperature in the causation of cutaneous burns.
      • Vangsness Jr., C.T.
      • Mitchell 3rd, W.
      • Nimni M.
      • Erlich M.
      • Saadat V.
      • Schmotzer H.
      Collagen shortening. An experimental approach with heat.
      Mean outcomes and standard deviation (SD) were calculated for ΔTmax and Δtden for the measurements of the experiments that were repeated 5 times. The SD in Figs. 3 and 4 are presented with vertical error bars; the horizontal error bars indicate uncertainty in measurement location.
      Figure thumbnail gr3
      Figure 3ΔTmax as a function of distance from the fiber tip for combinations of power (output) and pullback speed, left for 940 nm and right for 1470 nm. P, Power; W, watt; v, speed; r, radial distance.
      Figure thumbnail gr4
      Figure 4Comparison between wavelengths of ΔTmax at various power (output) levels and pullback speeds (v = 2 mm/s and v = 5 mm/s). P, Power; W, watt; v, speed; r, radial distance.

      Statistical Analyses

      Continuous variables are presented as means with a SD and were compared between groups using a Student t-test. We used Statistical Package for the Social Sciences (SPSS) 15.0 software (SPSS Inc., Chicago, IL, USA), and two-sided p-values were considered significant if <0.05.

      Results

      The results for ΔTmax, are graphically depicted per wavelength and by measured power (Fig. 3) and per pullback speed (Fig. 4) at radial distance r (mm) from the fibre tip. The time span that the temperature was above the threshold value for collagen denaturation (Δtden) is listed in Table 1.
      Table 1Values for Δtden (seconds), mean ± SD for three different power outputs
      Power output differed from power setting.
      and two pullback speeds.
      v = 2 [mm/s]
      4.6 W
      Power setting 5 W.
      4.6 W
      Power setting 5 W.
      12.8 W
      Power setting 14 W.
      12.8 W
      Power setting 14 W.
      18.3 W
      Power setting 20 W.
      r[mm]94014709401470940
      22.6 ± 2.92.3 ± 1.58.3 ± 1.49.7 ± 0.89.6 ± 1.8
      v = 5 [mm/s]
      4.6 W
      Power setting 5 W.
      4.6 W
      Power setting 5 W.
      12.8 W
      Power setting 14 W.
      12.8 W
      Power setting 14 W.
      18.3 W
      Power setting 20 W.
      r[mm]94014709401470940
      20.1 ± 0.10.0 ± 0.12.4 ± 1.51.5 ± 1.43.7 ± 1.5
      a Power output differed from power setting.
      b Power setting 5 W.
      c Power setting 14 W.
      d Power setting 20 W.
      Increasing the speed from 2 to 5 mm s−1 resulted in a decrease in ΔTmax for both wavelengths (Fig. 3). In addition, higher pullback speed resulted in lower Δtden (Table 1). Increasing the power level from 4.6 W to 12.8 W resulted in higher ΔTmax, but only a minor effect on ΔTmax was observed for a further increment to 18.3 W in the 940 nm laser wavelength (Figs. 3 and 4). However, Δtden increased nearly linearly with increasing power (Table 1).
      Since the measured power value at the fibre output proved to be lower than the set values during the experiments (power measurements: sensor Ophir 30 A (power accuracy ± 3%), meter Ophir Nova), with differences slightly depending on the laser used, an additional comparison was made using a measured power output of 12.8 W for both lasers. Variations in ΔTmax due to wavelength can only occur within a distance of about 2 mm from the laser tip (Fig. 5). More and more accurate measurements are required to give conclusive results regarding the wavelength dependency of the time-dependent temperature field around the fibre. The applied laser wavelengths (940 nm or 1470 nm) had only little effect on ΔTmax.
      Figure thumbnail gr5
      Figure 5Peak temperature values at 12.8 W. Variations in ΔTmax due to wavelength variation can only occur within a distance of about 2 mm from the line over which the laser tip is moving. P, Power; W, watt; v, speed; r, radial distance.
      Fig. 6 shows the temperature results using a varicose vein (GSV). Although the obtained maximum temperatures were higher than the temperatures in the glass tubes, the differences were not statistically significant for the combinations of different laser settings and distances to the laser tip, except for the 12.8 W, 5 mm s−1 at a distance of 3 mm (p = 0.02).
      Figure thumbnail gr6
      Figure 6Comparison of ΔTmax for experiments with a great saphenous vein (GSV) and a glass tube. P, Power; W, watt; v, speed; r, radial distance.

      Discussion

      Our simulated experiments of EVLA confirmed that pullback speed and power level both influence the temperature profile. We showed that only combinations of laser power and pullback speed that supply a relatively high administered energy per cm resulted in substantial Δtden values. At 940 nm, ΔTmax and Δtden increased when the power was increased from 4.6 W to 12.8 W and at 1470 nm, ΔTmax and Δtden increased when the power was increased from 4.6 W to 12.8 W. However, at 940 nm, when further increasing the power to 18.3 W, only the Δtden further increased and ΔTmax did not. This means that further increasing the power to 18.3 W at 940 nm may cause more damage to the vein wall. At 1470 nm, this experiment could not be performed because the power setting was limited to 14 W. The stagnation in maximum temperature is explained by noting that the maximum temperature approaches the boiling point, which limits further increase of temperature. Only combinations of power level and pullback speed that supply a relatively high administered energy per cm (approximately >60 J cm−1) result in substantial Δtden, which is in line with previous studies suggesting a threshold of 60 J cm−1 for durable vein occlusion.
      • Proebstle T.M.
      • Moehler T.
      • Herdemann S.
      Reduced recanalization rates of the great saphenous vein after endovenous laser treatment with increased energy dosing: definition of a threshold for the endovenous fluence equivalent.
      • Timperman P.E.
      • Sichlau M.
      • Ryu R.K.
      Greater energy delivery improves treatment success of endovenous laser treatment of incompetent saphenous veins.
      • Theivacumar N.S.
      • Dellagrammaticas D.
      • Beale R.J.
      • Mavor A.I.
      • Gough M.J.
      Factors influencing the effectiveness of endovenous laser ablation (EVLA) in the treatment of great saphenous vein reflux.
      It was not our aim to propose the appropriate energy dosing based on our experiments. Ideally, this should be based on a comparative randomised trial using different laser parameters studying effectiveness and side effects. However, based on our experimental data, we could hypothesise that, for effectiveness, at least 12.8 W in combination with a pullback speed of 2 mm s−1 should be administered independent of laser wavelength. To prevent side effects, it seems logical to prevent vein wall perforations by preventing direct contact of the laser tip with the vein wall, for example, by using a tulip piece around the tip.
      • Vuylsteke M.
      • Van Dorpe J.
      • Roelens J.
      • De Bo T.
      • Mordon S.
      • Fourneau I.
      Intraluminal fibre-tip centring can improve endovenous laser ablation: a histological study.
      The most important conclusion drawn from the experimental results is that the temperature profiles of 940 and 1470 nm laser wavelengths are virtually identical at equal pullback speed and power. The wavelengths used in this study cover the clinically applied range of wavelengths to a large extent. Light at 940 nm is primarily absorbed by haemoglobin with about 0.16 mm−1 blood absorption coefficient, very comparable to the 0.12–0.17 mm−1 blood absorption coefficients between 810 and 1064 nm,
      • Roggan A.
      • Friebel M.
      • Dorschel K.
      • Hahn A.
      • Muller G.
      Optical properties of circulating human blood in the wavelength range 400-2500 NM.
      and light at 1470 nm primarily by water with about 2.5 mm−1 blood absorption coefficient. The resulting temperature profiles are virtually identical for different laser wavelengths. Consequently, possible differences in outcome between different EVLA studies may not be explained by different laser wavelengths but rather by differences in other laser parameters such as pullback speed, power and fibre tip design.
      • Almeida J.
      • Mackay E.
      • Javier J.
      • Mauriello J.
      • Raines J.
      Saphenous laser ablation at 1470 nm targets the vein wall, not blood.
      In addition to virtually identical ΔTmax and Δtden for equal power and pullback speed for both 940 nm and 1470 nm laser wavelengths, the extreme temperature near the laser fibre tip is likely to be comparable as well. In a recent study, the tips of fibres used for 940 nm and 1470 nm were both damaged suggesting temperatures of more than 800 °C.
      • Amzayyb M.
      • van den Bos R.R.
      • Kodach V.M.
      • de Bruin D.M.
      • Nijsten T.
      • Neumann H.A.
      • et al.
      Carbonized blood deposited on fibres during 810, 940 and 1,470 nm endovenous laser ablation: thickness and absorption by optical coherence tomography.
      It has been suggested that only intraluminal thrombosis caused by EVLA may be sufficient for vein occlusion. If that is the case, our minimal threshold of 50 °C needed for collagen denaturation of the vein wall may not be needed. We based this threshold on the histological studies post-EVLA and the observation of RFA-induced venous remodelling assuming that collagen alteration is important for durable occlusion. However, changing the threshold of 50 °C to, for example, 40 °C would not change the conclusion of this study that a wavelength change from 940 nm to 1470 nm did not demonstrate a change in temperature rise.
      In the experiments with a varicose vein, peak temperatures were higher, but not statistically significant, to those measured in the glass tube. We hypothesise that the thermocouples were located closer to the fibre tip in the varicose vein because the vein might have been compressed and contracted during the experiments. A thermocouple location of only 0.5 mm closer to the fibre tip would already explain the increase in maximum temperatures in Fig. 6. Subcutaneous tissue and water have similar heat diffusivity. More importantly, also the glass tube material has a similar heat diffusivity of about 0.16 10−6 m2 s−1. Two significant transport mechanisms of heat, diffusion and radiation, are therefore virtually the same in actual veins and in the mock-up we employed. Altogether, the findings in the varicose vein and glass tube were very comparable confirming the validity of the experimental setting of a glass tube. The latter is also more suitable for the performed measurements because of its constant shape and position, yielding better reproducible measurement conditions.
      Our results are in line with a previous study in which we showed that fibre tips after EVLA had a carbonised layer of blood on the tip and destruction of the fibre glass was visible, suggesting that the temperature rise close to the fibre tip is high. These results were also independent of laser wavelength. The carbonised layer on the fibre tip absorbed between 30% and 70% of the laser light emission suggesting that heat diffusion is a major mechanism for EVLA, independent of wavelength.
      • Amzayyb M.
      • van den Bos R.R.
      • Kodach V.M.
      • de Bruin D.M.
      • Nijsten T.
      • Neumann H.A.
      • et al.
      Carbonized blood deposited on fibres during 810, 940 and 1,470 nm endovenous laser ablation: thickness and absorption by optical coherence tomography.
      This observation also supports two other temperature-related mechanisms, namely, steam bubble formation and direct contact of the fibre tip with the vein wall, since both mechanisms are based on exceedingly high fibre tip temperature.

      Conclusions

      The findings of this study are that increasing power (up to 18.3 W) and decreasing pullback speed (from 5 mm s−1 to 2 mm s−1) result in higher peak temperatures. Only a relatively high administered energy per unit length results in high enough temperatures to cause collagen denaturation. In addition, wavelength has not been demonstrated to be an important parameter to influence the temperature profile in EVLA. These observations suggest that the working mechanism of EVLA is independent of laser wavelength. In future studies, standardised clinical parameters based on this study could be applied and tested in a randomised clinical trial. A better understanding of the mechanism of action may contribute to achieving a consensus on the laser settings resulting in an optimal risk–benefit ratio (high effectiveness, with minimal adverse events).

      Conflict of Interest/Funding Statement

      There are no conflicts of interest.

      References

        • van den Bos R.
        • Arends L.
        • Kockaert M.
        • Neumann M.
        • Nijsten T.
        Endovenous therapies of lower extremity varicosities: a meta-analysis.
        J Vasc Surg. 2009; 49: 230-239
        • Van Den Bos R.R.
        • Neumann M.
        • De Roos K.P.
        • Nijsten T.
        Endovenous laser ablation-induced complications: review of the literature and new cases.
        Dermatol Surg. 2009; 35: 1206-1214
        • Proebstle T.M.
        • Moehler T.
        • Herdemann S.
        Reduced recanalization rates of the great saphenous vein after endovenous laser treatment with increased energy dosing: definition of a threshold for the endovenous fluence equivalent.
        J Vasc Surg. 2006; 44: 834-839
        • Timperman P.E.
        • Sichlau M.
        • Ryu R.K.
        Greater energy delivery improves treatment success of endovenous laser treatment of incompetent saphenous veins.
        J Vasc Interv Radiol. 2004; 15: 1061-1063
        • Theivacumar N.S.
        • Dellagrammaticas D.
        • Beale R.J.
        • Mavor A.I.
        • Gough M.J.
        Factors influencing the effectiveness of endovenous laser ablation (EVLA) in the treatment of great saphenous vein reflux.
        Eur J Vasc Endovasc Surg. 2008; 35: 119-123
        • Mordon S.R.
        • Wassmer B.
        • Zemmouri J.
        Mathematical modeling of 980-nm and 1320-nm endovenous laser treatment.
        Lasers Surg Med. 2007; 39: 256-265
        • Disselhoff B.C.
        • Rem A.I.
        • Verdaasdonk R.M.
        • Kinderen D.J.
        • Moll F.L.
        Endovenous laser ablation: an experimental study on the mechanism of action.
        Phlebology. 2008; 23: 69-76
        • Proebstle T.M.
        • Lehr H.A.
        • Kargl A.
        • Espinola-Klein C.
        • Rother W.
        • Bethage S.
        • et al.
        Endovenous treatment of the greater saphenous vein with a 940-nm diode laser: thrombotic occlusion after endoluminal thermal damage by laser-generated steam bubbles.
        J Vasc Surg. 2002; 35: 729-736
        • van der Geld C.W.
        • van den Bos R.R.
        • van Ruijven P.W.
        • Nijsten T.
        • Neumann H.A.
        • van Gemert M.J.
        The heat-pipe resembling action of boiling bubbles in endovenous laser ablation.
        Lasers Med Sci. 2010; 25: 907-909
        • Fan C.M.
        • Rox-Anderson R.
        Endovenous laser ablation: mechanism of action.
        Phlebology. 2008; 23: 206-213
        • van den Bos R.R.
        • Kockaert M.A.
        • Martino Neumann H.A.
        • Bremmer R.H.
        • Nijsten T.
        • van Gemert M.J.
        Heat conduction from the exceedingly hot fiber tip contributes to the endovenous laser ablation of varicose veins.
        Lasers Med Sci. 2009; 24: 247-251
        • Viarengo L.M.
        • Poterio-Filho J.
        • Poterio G.M.
        • Menezes F.H.
        • Meirelles G.V.
        Endovenous laser treatment for varicose veins in patients with active ulcers: measurement of intravenous and perivenous temperatures during the procedure.
        Dermatol Surg. 2007; 33 (discussion 41–42): 1234-1242
        • Weiss R.A.
        Comparison of endovenous radiofrequency versus 810 nm diode laser occlusion of large veins in an animal model.
        Dermatol Surg. 2002; 28: 56-61
        • Zimmet S.E.
        • Min R.J.
        Temperature changes in perivenous tissue during endovenous laser treatment in a swine model.
        J Vasc Interv Radiol. 2003; 14: 911-915
        • Vuylsteke M.
        • Van Dorpe J.
        • Roelens J.
        • De Bo T.
        • Mordon S.
        • Fourneau I.
        Intraluminal fibre-tip centring can improve endovenous laser ablation: a histological study.
        Eur J Vasc Endovasc Surg. 2010; 40: 110-116
        • Biesman B.S.
        • Khan J.
        Laser incisional surgery.
        Clin Plast Surg. 2000; 27 ([x]): 213-220
        • Moritz A.R.
        • Henriques F.C.
        Studies of thermal injury: II. The relative importance of time and surface temperature in the causation of cutaneous burns.
        Am J Pathol. 1947; 23: 695-720
        • Vangsness Jr., C.T.
        • Mitchell 3rd, W.
        • Nimni M.
        • Erlich M.
        • Saadat V.
        • Schmotzer H.
        Collagen shortening. An experimental approach with heat.
        Clin Orthop Relat Res. 1997; : 267-271
        • Roggan A.
        • Friebel M.
        • Dorschel K.
        • Hahn A.
        • Muller G.
        Optical properties of circulating human blood in the wavelength range 400-2500 NM.
        J Biomed Opt. 1999; 4: 36-46
        • Almeida J.
        • Mackay E.
        • Javier J.
        • Mauriello J.
        • Raines J.
        Saphenous laser ablation at 1470 nm targets the vein wall, not blood.
        Vasc Endovascular Surg. 2009; 43: 467-472
        • Amzayyb M.
        • van den Bos R.R.
        • Kodach V.M.
        • de Bruin D.M.
        • Nijsten T.
        • Neumann H.A.
        • et al.
        Carbonized blood deposited on fibres during 810, 940 and 1,470 nm endovenous laser ablation: thickness and absorption by optical coherence tomography.
        Lasers Med Sci. 2010; 25: 439-447

      Comments

      Commenting Guidelines

      To submit a comment for a journal article, please use the space above and note the following:

      • We will review submitted comments as soon as possible, striving for within two business days.
      • This forum is intended for constructive dialogue. Comments that are commercial or promotional in nature, pertain to specific medical cases, are not relevant to the article for which they have been submitted, or are otherwise inappropriate will not be posted.
      • We require that commenters identify themselves with names and affiliations.
      • Comments must be in compliance with our Terms & Conditions.
      • Comments are not peer-reviewed.